کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4225287 | 1609759 | 2014 | 8 صفحه PDF | دانلود رایگان |

• We evaluate 3D PSIR compared with 3D IR for the detection of myocardial scars.
• In image quality, there was no significant difference between IR and PSIR.
• A quantitative analysis of LGE volume shows a strong correlation between PSIR and IR.
• PSIR detected greater LGE volume in non-ischemic cardiomyopathy patients than IR.
• PSIR may have a specific role in scar evaluation of non-ischemic cardiomyopathy.
BackgroundLate gadolinium enhancement (LGE) magnetic resonance imaging (MRI) is a useful technique for detecting myocardial fibrosis. LGE images are typically acquired using the inversion recovery (IR) method. Recently, phase-sensitive inversion recovery (PSIR) technology has been developed. The purpose of this study was to evaluate free-breathing 3D PSIR sequencing in comparison with breath-held 3D IR sequencing for the detection of myocardial fibrosis.MethodsOne hundred twenty-three patients with suspected ischemic cardiac disease (n = 27) or non-ischemic cardiomyopathy (hypertrophic cardiomyopathy, n = 29; dilated cardiomyopathy, n = 22; sarcoidosis, n = 21; arrhythmia, n = 9; myocarditis, n = 4; amyloidosis, n = 3; and others, n = 8) were evaluated by LGE–MRI, which was performed first with the IR sequence and then with the PSIR sequence, using a 3 T MRI scanner. Image quality was scored by two independent readers using a four-point scale. The 3D LGE volume was analyzed quantitatively and compared between both sequencing methods.ResultsThere was no significant difference in overall image quality (p = 0.19). LGE was detected in 73 patients, who were evaluated visually. Ultimately, 58 patients with acceptable image quality were enrolled in further quantitative analyses (volume assessment). Although quantification of LGE volume revealed a strong correlation between both methods, larger LGE volumes were detected with PSIR compared to IR in patients suspected of non-ischemic cardiomyopathy (39.5 ± 25.9 cm3 for PSIR and 32.8 ± 23.9 cm3 for IR, p < 0.001). The LGE volume did not differ significantly in patients suspected of ischemic cardiac disease (17.9 ± 12.7 cm3 for PSIR and 17.5 ± 11.1 cm3 for IR, p = 0.34).Conclusions3D PSIR is suitable for detection of LGE and may be an option in cases with IR images of unacceptable quality but overestimates LGE volume in non-ischemic cardiomyopathy.
Journal: European Journal of Radiology - Volume 83, Issue 12, December 2014, Pages 2159–2166