کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4225519 1609760 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The performance of MRI in detecting subarticular bone erosion of sacroiliac joint in patients with spondyloarthropathy: A comparison with X-ray and CT
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی رادیولوژی و تصویربرداری
پیش نمایش صفحه اول مقاله
The performance of MRI in detecting subarticular bone erosion of sacroiliac joint in patients with spondyloarthropathy: A comparison with X-ray and CT
چکیده انگلیسی


• MRI 3D-WS-bSSFP sequence has high spatial resolution and short scanning time.
• This is the first time this sequence was applied to detect bone erosion of SI joint.
• Its performance was compared with other commonly used diagnostic methods.
• Result shows that this sequence is better than X-ray and T1W in the detection of bone erosion.
• This sequence can be considered an alternative to CT in showing erosion in SpA patients.

ObjectiveTo assess the sensitivity and specificity of detecting subarticular bone erosion of sacroiliac (SI) joint in patients with spondyloarthritis (SpA) using MRI three-dimensional water selective balanced steady-state free precession sequence (3D-WS-bSSFP) and T1-weighted (T1W) sequence.Materials and methodsRadiography, CT and MRI of SI joint from 43 SpA patients were retrospectively analyzed. MRI examination sequences include T1W, short tau inversion recovery (STIR) and 3D-WS-bSSFP. Two radiologists, blinded to clinical data, independently determined bone erosion at bilateral sacral and iliac sides of the SI joint on radiography, CT, T1W and 3D-WS-bSSFP respectively. X2 test was used to compare the sensitivity of detecting bone erosion among different diagnostic methods.ResultsOf the 86 sacral and 86 iliac articular surfaces from the 43 cases, radiography, CT, MRI T1W and 3D-WS-bSSFP showed the presence of bone erosion in 40, 74, 50 and 71 articular surfaces respectively. CT and MRI 3D-WS-bSSFP demonstrated similar sensitivity (x2 = 0.11, P = 0.74), and both were superior to radiography (x2 = 15.17, P < 0.01 and x2 = 12.78, P < 0.01, respectively) and T1W (x2 = 7.26, P < 0.01 and x2 = 5.62, P < 0.05). Using CT diagnosis as the gold standard, the sensitivity and specificity of detecting bone erosion for MRI 3D-WS-bSSFP and T1W sequences were 91.8%, 96.9%, and 60.8%, 94.9% respectively.ConclusionMRI 3D-WS-bSSFP sequence is associated with short scanning time, zero ionizing radiation, high sensitivity and specificity of displaying the subarticular bone erosion of SI joints in patients with SpA. Therefore, it can be considered an alternative to CT.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Radiology - Volume 83, Issue 11, November 2014, Pages 2058–2064
نویسندگان
, , , , , , ,