A methodology to evaluate differential costs of full field digital as compared to conventional screen film mammography in a clinical setting
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی رادیولوژی و تصویربرداری
پیش نمایش صفحه اول مقاله
A methodology to evaluate differential costs of full field digital as compared to conventional screen film mammography in a clinical setting
چکیده انگلیسی

PurposeThe use of full field digital mammography (FFDM) in alternative to conventional screen film mammography (SFM) in the current practice is delayed by the high costs of FFDM. The present study, performed at the Centro per lo Studio e la Prevenzione Oncologica of Florence, using both FFDM and SFM, was aimed at estimating the impact of introducing the new FFDM technique on overall mammography costs.Material and methodsWe estimated the differential costs of both methods, based on real expenditures, as provided by the administrative department, and on radiologists, radiographers and other staff's working time. Two different workload scenarios (5000 and 10,000 tests/year per mammography equipment) were considered. Common costs of both techniques were censored for study purpose.ResultsBeside a higher cost due to purchase and hire/leasing costs of equipment, FFDM implies a greater workload for radiologists (reading time almost doubled). SFM implies a greater workload for the administrative staff to run the archive and for loading/unloading films of the roller viewer, whereas no different workload has been observed for radiographers. Overall FFDM costs €24.22–26.46 for examination more than SFM for the 5000 tests scenario and €9.91–12.15 more for the 10,000 tests scenario.DiscussionAlthough present study estimates cannot easily be generalised to any local setting, the model for cost calculation is easy to be exported to another scenario by applying different local parameters. The advantages made available by FFDM (computerised data recording, tele-transmission, tele-reporting, tele-consulting, automatic display on monitor of previous exams and use of CAD) may justify the higher cost, but a limited reduction in purchase and assistance costs could easily allow a turnover, with FFDM being more convenient than SFM even on the cost side.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Radiology - Volume 57, Issue 1, January 2006, Pages 69–75
نویسندگان
, , , ,