The present report describes a simple technique for tantalum coating of microspheres for visualization by fluoroscopy and computed tomography (CT). Spherical microspheres were soaked with Ta powder under different conditions and microscopically evaluated for Ta-coating quality by assessing bound and unbound Ta. For 100-300-µm Embosphere particles, soaking with 0.05 mL Ta powder for 30 minutes and centrifugation at 500 rpm produced optimal coating. Optimized microspheres were injected in swine renal arteries and assessed by fluoroscopy and micro-CT for the opacification of segmental, arcuate, and interlobular arteries. This practical method can be used for experimental studies with commonly available microspheres.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Vascular and Interventional Radiology - Volume 27, Issue 1, January 2016, Pages 127-132