کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4408970 1618873 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
PCDD/DF and co-planar PCB emissions from crematories in Japan
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست شیمی زیست محیطی
پیش نمایش صفحه اول مقاله
PCDD/DF and co-planar PCB emissions from crematories in Japan
چکیده انگلیسی


• Concentrations of PCDDs/DFs and co-PCBs in some media from crematories were measured as a Japanese follow-up investigation.
• Dioxin emission factors via flue gas for 2007 were significantly lower than those for 1999.
• The implementation of dioxin emission standards in Japan has been successful in reducing dioxin emissions from crematoriums.
• TEQ concentrations of dioxins in bottom ash (mainly bone) were very low and ranged from 0 to 0.042 ng-TEQ g−1.
• Fly ash from some facilities with a heat exchanger contained higher dioxins, because of secondary formation of dioxins.

Japan implemented dioxin emission guidelines for crematories in 2000, but the effects of the new guidelines have not been fully evaluated. In this study, concentrations of polychlorinated dibenzodioxins/dibenzofurans (PCDDs/DFs) and co-planar polychlorinated biphenyls (co-PCBs) were measured in flue gas, fly ash, and bottom ash (mainly bone) from several crematories as a follow-up investigation. Total concentrations (O2 12% normalized) of PCDDs/DFs and co-PCBs in flue gas ranged from 4.2to540ng/mN3, and toxic equivalent concentrations ranged from 0.000053 to 11ng-TEQ/mN3. Based on these measurements, the average emission factor was estimated to be 1400 ng-TEQ/body. This is approximately one-third the emission factor recorded in 1999. The emission factor distributions from 1999 and our study in 2007 were log-normally distributed. Emission factors were significantly lower in 2007 than in 1999, which suggests that the guidelines have been effective in reducing dioxin emissions. Meanwhile, toxic equivalent concentrations in fly ash ranged from 0.014 to 13 ng-TEQ g−1. Higher dioxin concentrations in fly ash were observed in facilities that used a heat exchanger as a flue-gas cooling device. Because the concentrations of PCDDs/DFs and co-PCBs in flue gas were also elevated after heat exchangers during the investigation of PCDD/DF- and co-PCB-removal behaviors, secondary formation of PCDDs/DFs and co-PCBs on heat exchanger surfaces unambiguously occurred.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemosphere - Volume 98, March 2014, Pages 91–98
نویسندگان
, , , ,