کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4410807 1307564 2011 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Rapid determination of dichlorodiphenyltrichloroethane and its main metabolites in aqueous samples by one-step microwave-assisted headspace controlled-temperature liquid-phase microextraction and gas chromatography with electron capture detection
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست شیمی زیست محیطی
پیش نمایش صفحه اول مقاله
Rapid determination of dichlorodiphenyltrichloroethane and its main metabolites in aqueous samples by one-step microwave-assisted headspace controlled-temperature liquid-phase microextraction and gas chromatography with electron capture detection
چکیده انگلیسی

A rapid and sensitive analytical method for the determination of dichlorodiphenyltrichloroethane (DDT) and its main metabolites in environmental aqueous samples has been developed using one-step microwave-assisted headspace controlled-temperature liquid-phase micro-extraction (MA-HS-CT-LPME) technique coupled with gas chromatography–electron-capture detection (GC–ECD). In this study, the one-step extraction of DDT and its main metabolites was achieved by using microwave heating to accelerate the evaporation of analytes into the controlled-temperature headspace to form a cloudy mist vapor zone for LPME sampling. Parameters influencing extraction efficiency were thoroughly optimized, and the best extraction for DDT and its main metabolites from 10-mL aqueous sample at pH 6.0 was achieved by using 1-octanol (4-μL) as the LPME solvent, sampling at 34 °C for 6.5 min under 249 W of microwave irradiation. Under optimum conditions, excellent linear relationship was obtained in the range of 0.05–1.0 μg/L for 1-dichloro-2,2-bis-(p′-chlorophenyl)ethylene (p,p′-DDE), 0.1–2.0 μg/L for o,p′-DDT, 0.15–3.0 μg/L for 1,1-dichloro-2,2-bis-(p′-chlorophenyl)ethane (p,p′-DDD) and p,p′-DDT, with detection limits of 20 ng/L for p,p′-DDE, and 30 ng/L for o,p′-DDT, p,p′-DDD and p,p′-DDT. Precision was in the range of 3.2–11.3% RSD. The proposed method was validated with environmental water samples. The spiked recovery was between 95.5% and 101.3% for agricultural-field water, between 94% and 99.7% for sea water and between 93.5% and 98% for river water. Thus the established method has been proved to be a simple, rapid, sensitive, inexpensive and eco-friendly procedure for the determination of DDT and its main metabolites in environmental water samples.

Research highlights
► One-step microwave-assisted headspace controlled-temperature LPME method was developed.
► Fast determination of DDT and its main metabolites in waters by GC–ECD was achieved.
► Microwave was used to accelerate the evaporation of analytes into cloud vapor zone.
► Achieved good linearity, precision and low detection limits.
► It is a simple, rapid, sensitive, inexpensive and eco-friendly method.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemosphere - Volume 83, Issue 2, March 2011, Pages 200–207
نویسندگان
, ,