A solid-phase microextraction – coupled to a gas chromatography – ion trap tandem mass spectrometry (SPME–GC–MS/MS) method was developed for the quantitative determination in rainwater of 8 pesticides amongst the most used in France and 3 triazines metabolites. The main factors affecting the SPME process were studied. Using a 3 mL sample, the method developed showed good linearity for concentrations ranging from 0.05 to 50 μg L−1 with correlation coefficients between 0.997 and 0.9999 and relative standard deviations (% RSD) below 14%. The study of matrix effects showed that rainwater was too diluted to have any significant influence on the extraction efficiency. To validate the method, a field campaign was carried out on the rain events, which occurred in Strasbourg during a one-year period. The rain concentrations showed patterns of high pesticide concentrations during spring months, which were correlated to the spraying periods of most of these substances.
Journal: Environmental Pollution - Volume 139, Issue 1, January 2006, Pages 133–142