کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4482237 1316852 2013 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Species-dependence of cyanobacteria removal efficiency by different drinking water treatment processes
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات فرآیندهای سطح زمین
پیش نمایش صفحه اول مقاله
Species-dependence of cyanobacteria removal efficiency by different drinking water treatment processes
چکیده انگلیسی

Accumulation and breakthrough of several potentially toxic cyanobacterial species within drinking water treatment plants (DWTP) have been reported recently. The objectives of this project were to test the efficiency of different treatment barriers in cyanobacterial removal. Upon observation of cyanobacterial blooms, intensive sampling was conducted inside a full scale DWTP at raw water, clarification, filtration and oxidation processes. Samples were taken for microscopic speciation/enumeration and microcystins analysis. Total cyanobacteria cell numbers exceeded World Health Organisation and local alert levels in raw water (6,90,000 cells/mL). Extensive accumulation of cyanobacteria species in sludge beds and filters, and interruption of treatment were observed. Aphanizomenon cells were poorly coagulated and they were not trapped efficiently in the sludge. It was also demonstrated that Aphanizomenon cells passed through and were not retained over the filter. However, Microcystis, Anabaena, and Pseudanabaena cells were adequately removed by clarification and filtration processes. The breakthrough of non toxic cyanobacterial cells into DWTPs could also result in severe treatment disruption leading to plant shutdown. Application of intervention threshold values restricted to raw water does not take into consideration the major long term accumulation of potentially toxic cells in the sludge and the risk of toxins release. Thus, a sampling regime inside the plant adapted to cyanobacterial occurrence and intensity is recommended.

Figure optionsDownload high-quality image (162 K)Download as PowerPoint slideHighlights
► Fate of 4 cyanobacterial genera in an operational treatment plant was studied.
► Poor coagulation and clarification of Aphanizomenon cells.
► Breakthrough of Aphanizomenon cells into filtered water.
► Recommendation of regular sampling inside water treatment plants.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Water Research - Volume 47, Issue 8, 15 May 2013, Pages 2689–2700
نویسندگان
, , , , , , ,