Four UV filters, benzophenone-3 (BP-3), 4-methylbenzylidence camphor (4-MBC), ethylhexyl methoxycinnamate (EHMC), and octocrylene (OC), have been examined along the different units of a wastewater reclamation plant (WWRP) located in Tianjin, North China. The analytical procedure included solid-phase extraction and gas chromatographic/mass spectrometric analyses. All four UV filters were detected in the influent during the three sampling campaigns (February, July, and September), and the concentrations ranged from 34 to 2128 ng L−1. The concentrations of the four UV filters were higher in hot weather (July and September) than in cool weather (February). The monthly average removal ranged from 7.6% to 21% for the selected UV filters during coagulation–flocculation (C–F) treatment. The ozonation treatment achieved the maximum removal (16–28%); on the contrary, the continuous microfiltration (CMF) achieved the lowest removal (3.6–8.2%). The total removal efficiencies along the plant varied from 28% to 43%. These results indicate that the UV filters are not completely removed during WWRP treatment and may be carried over into the environment during the reuse applications.
Journal: Water Research - Volume 41, Issue 15, August 2007, Pages 3506–3512