کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4486478 1316990 2007 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A simple method for the measurement of organic iodine in wastewater and surface water
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات فرآیندهای سطح زمین
پیش نمایش صفحه اول مقاله
A simple method for the measurement of organic iodine in wastewater and surface water
چکیده انگلیسی

Total adsorbable organic iodine (TAOI) has been used as a surrogate parameter for X-ray contrast media in municipal wastewater. Available methods require specialized equipment for pyrolyzing these compounds to convert the covalently bound iodine into iodide, which is then measured by ion chromatography. In this study we describe a simple method for liberating iodide from these compounds with Cu(II) and hydrogen peroxide. Concentrations of TAOI were measured in wastewater effluent, surface waters that were expected to be impacted by wastewater, and unimpacted surface waters. TAOI concentrations ranged between 1.9 and 16.3 μg/L I in wastewater with a median of 6.5 μg/L I. The lowest TAOI concentrations consistently were detected in a wastewater treatment plant that apparently had few hospitals within its collection area. In comparison, TAOI concentrations in surface water that was unimpacted by sewage were between 0.3 and 3.5 μg/L I. TAOI concentrations in surface waters that were impacted by sewage were consistent with the expected conservative behavior of TAOI.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Water Research - Volume 41, Issue 7, April 2007, Pages 1580–1586