کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4577934 1630043 2010 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A rainwater harvesting system reliability model based on nonparametric stochastic rainfall generator
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات فرآیندهای سطح زمین
پیش نمایش صفحه اول مقاله
A rainwater harvesting system reliability model based on nonparametric stochastic rainfall generator
چکیده انگلیسی

SummaryThe reliability with which harvested rainwater can be used as a means of flushing toilets, irrigating gardens, and topping off air-conditioner serving multifamily residential buildings in New York City is assessed using a new rainwater harvesting (RWH) system reliability model. Although demonstrated with a specific case study, the model is portable because it is based on a nonparametric rainfall generation procedure utilizing a bootstrapped markov chain. Precipitation occurrence is simulated using transition probabilities derived for each day of the year based on the historical probability of wet and dry day state changes. Precipitation amounts are selected from a matrix of historical values within a moving 15 day window that is centered on the target day. RWH system reliability is determined for user-specified catchment area and tank volume ranges using precipitation ensembles generated using the described stochastic procedure. The reliability with which NYC backyard gardens can be irrigated and air conditioning units supplied with water harvested from local roofs exceeds 80% and 90%, respectively, for the entire range of catchment areas and tank volumes considered in the analysis. For RWH systems installed on the most commonly occurring rooftop catchment areas found in NYC (51–75 m2), toilet flushing demand can be met with 7–40% reliability, with lower end of the range representing buildings with high flow toilets and no storage elements, and the upper end representing buildings that feature low flow fixtures and storage tanks of up to 5 m3. When the reliability curves developed are used to size RWH systems to flush the low flow toilets of all multifamily buildings found a typical residential neighborhood in the Bronx, rooftop runoff inputs to the sewer system are reduced by approximately 28% over an average rainfall year, and potable water demand is reduced by approximately 53%.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Hydrology - Volume 392, Issues 3–4, 15 October 2010, Pages 105–118
نویسندگان
, , ,