کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4993595 1458031 2017 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Flow boiling of R245fa in the brazed plate heat exchanger: Thermal and hydraulic performance assessment
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Flow boiling of R245fa in the brazed plate heat exchanger: Thermal and hydraulic performance assessment
چکیده انگلیسی
Present study deals with the flow boiling of R245fa, a commercial working fluid used in organic Rankine cycle, in brazed plate heat exchanger with chevron angle of 45 degree and 60 degree. The effects of the heat flux, mass flux rate of refrigerant, saturation temperature on convective heat transfer coefficients are investigated. The operating conditions of the experiment are as mass flux: 30-40 kg m−2 s−1 quality at evaporator inlet: 0.1-0.8, heat flux: 2-15 kW m−2. The heat transfer result suggests a nucleate boiling dominant process in the evaporator. The convective heat transfer coefficient showed a strong dependence on the heat flux and vapor quality at evaporator inlet. Moreover convective heat transfer coefficient show a linear relationship with mass flux of the refrigerant. It is worth mentioning that heat transfer coefficient is higher at higher saturation temperature and chevron angle. Based on the experimental data, empirical correlations were developed for the prediction of heat transfer coefficients and frictional pressure drop of refrigerant R245fa in brazed plate heat exchanger.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Heat and Mass Transfer - Volume 110, July 2017, Pages 657-670
نویسندگان
, , , ,