کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
5013225 | 1462827 | 2017 | 11 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Modelling and exergoeconomic-environmental analysis of combined cycle power generation system using flameless burner for steam generation
ترجمه فارسی عنوان
مدل سازی و تجزیه و تحلیل محیطی اقتصادی-اقتصادی با استفاده از سیستم تولید انرژی چرخه ترکیبی با استفاده از مشعل فلوئور برای تولید بخار
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
GHGsACTBFPEVAPDEAECOLHVHRSGCRFTITDeaeratorSFsCCPPCooling water - آب خنک کنFlameless combustion - احتراق احتراقProbability - احتمالات، احتمالeconomizer - اقتصادزاExergy - اکسرژیIsentropic - ایزنتروپیکEfficiency - بازده evaporator - تبخیرکننده، اواپراتورDestruction - تخریبSteam turbine - توربین بخارGas turbine - توربین گازgas constant - ثابت گازHeat - حرارتTurbine inlet temperature - دمای ورودی توربینFuel - سوختSup - سوپSuperheat - سوپر هیتChemical - شیمیاییcapital recovery factor - عامل بازیابی سرمایهHigh pressure - فشار بالاLow pressure - فشار کمPhysical - فیزیکیCond - مسکنHeat recovery steam generator - مولد بخار با توان بازیافت حرارتPinch point - نقطه ضعفCombined cycle power plant - نیروگاه چرخه ترکیبیAIR - هواactual - واقعیCombined cycle - چرخه ترکیبیAir compressor - کمپرسور هواCondenser - کندانسورGreenhouse gases - گازهای گلخانه ای
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی انرژی
انرژی (عمومی)
چکیده انگلیسی
To have an optimum condition for the performance of a combined cycle power generation, using supplementary firing system after gas turbine was investigated by various researchers. Since the temperature of turbine exhaust is higher than auto-ignition temperature of the fuel in optimum condition, using flameless burner is modelled in this paper. Flameless burner is installed between gas turbine cycle and Rankine cycle of a combined cycle power plant which one end is connected to the outlet of gas turbine (as primary combustion oxidizer) and the other end opened to the heat recovery steam generator. Then, the exergoeconomic-environmental analysis of the proposed model is evaluated. Results demonstrate that efficiency of the combined cycle power plant increases about 6% and CO2 emission reduces up to 5.63% in this proposed model. It is found that the variation in the cost is less than 1% due to the fact that a cost constraint is implemented to be equal or lower than the design point cost. Moreover, exergy of flow gases increases in all points except in heat recovery steam generator. Hence, available exergy for work production in both gas cycle and steam cycle will increase in new model.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy Conversion and Management - Volume 135, 1 March 2017, Pages 362-372
Journal: Energy Conversion and Management - Volume 135, 1 March 2017, Pages 362-372
نویسندگان
Seyed Ehsan Hosseini, Hasan Barzegaravval, Abdolsaeid Ganjehkaviri, Mazlan Abdul Wahid, M.N. Mohd Jaafar,