کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5130879 1490863 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An ultra-specific and sensitive sandwich ELISA for imatinib using two anti-imatinib antibodies
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
An ultra-specific and sensitive sandwich ELISA for imatinib using two anti-imatinib antibodies
چکیده انگلیسی


- We developed a sandwich ELISA for detecting the low-molecular-weight drug imatinib.
- The sandwich ELISA exhibited ultra-specificity for imatinib.
- Imatinib represents the smallest drug molecule to be analyzed by the noncompetitive ELISA format.

The development of an immunoassay for a low-molecular-weight drug first requires the identification of specific antibodies that do not cross-react with the drug's metabolites. If two antibodies can simultaneously recognize the entire structure of the drug, we can then utilize them to establish an ultra-specific sandwich ELISA, free from interference due to the metabolic products of the drug. This paper reports an ultra-specific and sensitive sandwich ELISA for determination of the tyrosine kinase inhibitor imatinib using two anti-imatinib antibodies. The anti-imatinib antibodies were obtained by two partial structures of imatinib as haptens (2-(5-amino-2-methylanilino)-4-(3-pyridyl)pyrimidine and 4-{(4-methyl-1-piperazinyl)-methyl}-benzoate). Under optimized conditions, this sandwich ELISA shows a linear detection range from 64 pg mL−1 to 8 ng mL−1, and a limit of detection of approximately 64 pg mL−1 for 100-μL samples. The ELISA is specific to imatinib and while there was no cross-reactivity with the major metabolite N-desmethyl-imatinib, slight cross-reactivity was found with metabolite pyridine-N-oxide-imatinib. This assay demonstrated significantly lower cross-reactivity with metabolites than competitive ELISAs. Using this assay, drug levels were easily measured in rat blood after oral administration of imatinib via a single dose of 30 mg kg−1 or 100 mg kg−1. The levels in rat serum measured by this ELISA were comparable with those measured by HPLC, and there was a strong correlation between the values determined by the two methods (y = 0.983x + 0.081, R2 = 0.948). Thus, we have successfully developed the first specific and sensitive sandwich ELISA for imatinib using two anti-imatinib antibodies. This sandwich ELISA will be a valuable tool for therapeutic drug monitoring and pharmacokinetic studies of imatinib.

116

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 969, 29 May 2017, Pages 72-78
نویسندگان
, , , , , , ,