کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5130900 1490866 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simultaneous metabolomics and lipidomics analysis based on novel heart-cutting two-dimensional liquid chromatography-mass spectrometry
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Simultaneous metabolomics and lipidomics analysis based on novel heart-cutting two-dimensional liquid chromatography-mass spectrometry
چکیده انگلیسی


- A 2D-LC-MS method based on a heart-cutting and column switching strategy was established.
- Comprehensive information of metabolome and lipidome was simultaneously covered within one injection for the first time.
- The method was suitable to large-scale metabolomics studies with small amount of samples.

Increasing metabolite coverage by combining data from different platforms or methods can improve understanding of related metabolic mechanisms and the identification of biomarkers. However, no one method can obtain metabolomic and lipidomic information in a single analysis. In this work, aiming at collecting comprehensive information on metabolome and lipidome in a single analytical run, we developed an on-line heart-cutting two-dimensional liquid chromatography-mass spectrometry (2D-LC-MS) method. Complex metabolites from biological samples are divided into two fractions by using a precolumn. The first fraction is directly transferred and subjected to metabolomics analysis. Most lipids are retained on the precolumn until the mobile phases for lipidomics flow through; then they are subjected to lipidomics analysis. Up to 447 and 289 metabolites in plasma, including amino acids, carnitines, bile acids, free fatty acids, lyso-phospholipids, phospholipids, sphingomyelins etc. were identified within 30 min in the positive mode and negative mode, respectively. A comparison of the newly developed method with the conventional metabolomic and lipidomic approaches showed that approximately 99% features obtained by the two conventional methods can be covered with this 2D-LC method. Analytical characteristics evaluation showed the method had a wide linearity range, high sensitivity, satisfactory recovery and repeatability. These results demonstrate that this method is reliable, stable and well qualified in metabolomics analysis, particularly for large-scale metabolomics studies with small amount of samples.

229

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 966, 8 May 2017, Pages 34-40
نویسندگان
, , , , ,