کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5131089 1490867 2017 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A new configuration for bar adsorptive microextraction (BAμE) for the quantification of biomarkers (hexanal and heptanal) in human urine by HPLC providing an alternative for early lung cancer diagnosis
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
A new configuration for bar adsorptive microextraction (BAμE) for the quantification of biomarkers (hexanal and heptanal) in human urine by HPLC providing an alternative for early lung cancer diagnosis
چکیده انگلیسی


- The bar adsorptive was impregnated with a derivatization reagent on its surface containing a biosorbent material.
- Derivatization reaction and the extraction occurred simultaneously on the surface of the bar under acidic conditions.
- The limits of detection for hexanal and heptanal were 0.80 and 0.40 μmol L−1, respectively.
- The method is of low cost and can be used for the quantification of two lung cancer biomarkers in human urine samples.

In this paper, a remodeling of the bar adsorptive microextraction (BAμE) technique is proposed with impregnation of the derivatization reagent on the surface of the adsorptive bar containing a biosorbent material. The derivatization reagent was 2,4-dinitrophenylhydrazine (DNPH), which was adsorbed on the surface of the bar containing cork powder as the extractor phase for the determination of two aldehydes (hexanal and heptanal) which are known as lung cancer biomarkers in human urine samples. The derivatization reaction and the extraction occurred simultaneously on the surface of the bar (length 7.5 mm) under acidic conditions. The method optimization was carried out by univariate and multivariate analysis. The optimal conditions for the method were a DNPH to aldehydes ratio of 40:1, buffer solution of pH 4.0, extraction time of 60 min and liquid desorption of 10 min in 100 μL of acetonitrile. The aldehydes were analyzed by HPLC-DAD with a simple and fast (6 min) chromatographic run. The limits of detection (LODs) for hexanal and heptanal were 1.00 and 0.73 μmol L−1, respectively. The relative recoveries in urine samples ranged from 88 to 111% with relative standard deviations (RSDs) being less than 7%. The method developed is of low cost and can be successfully used for the quantification of these two lung cancer biomarkers in human urine samples, potentially providing an early diagnosis of lung cancer.

207

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 965, 1 May 2017, Pages 54-62
نویسندگان
, , , ,