کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5131195 1490868 2017 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Biofunctional polyelectrolytes assembling on biosensors - A versatile surface coating method for protein detections
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Biofunctional polyelectrolytes assembling on biosensors - A versatile surface coating method for protein detections
چکیده انگلیسی


- An efficient and convenient immunoassay was developed based on PLL-g-OEGx-Biotin.
- Compatible with different sensor platform (QCM, Interferometry, ELISA).
- Optimization of grafted OEG chain length for immunoassay.
- Successful detection of human PSA with a LOD of 0.5 nM.
- Complete sensor regeneration simply by a mild pH stimulation.

This paper reports a surface functionalization strategy for protein detections based on biotin-derivatized poly(l-lysine)-grafted oligo-ethylene glycol (PLL-g-OEGx-Biotin) copolymers. Such strategy can be used to attach the biomolecule receptors in a reproducible way simply by incubation of the transducer element in a solution containing such copolymers which largely facilitated the sensor functionalization at an industrial scale. As the synthesized copolymers are cationic in physiology pH, surface biotinylation can be easily achieved via electrostatic adsorption on negatively charged sensor surface. Biotinylated receptors can be subsequently attached through well-defined biotin-streptavidin interaction. In this work, the bioactive sensor surfaces were applied for mouse IgG and prostate specific antigen (PSA) detections using quartz crystal microbalance (QCM), optical sensor (BioLayer Interferometry) and conventional ELISA test (colorimetry). A limit of detection (LOD) of 0.5 nM was achieved for PSA detections both in HEPES buffer and serum dilutions in ELISA tests. The synthesized PLL-g-OEGx-Biotin copolymers with different OEG chain length were also compared for their biosensing performance. Moreover, the surface regeneration was achieved by pH stimulation to remove the copolymers and the bonded analytes, while maintaining the sensor reusability as well. Thus, the developed PLL-g-OEGx-Biotin surface assembling strategy is believed to be a versatile surface coating method for protein detections with multi-sensor compatibility.

263

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 964, 29 April 2017, Pages 170-177
نویسندگان
, , ,