کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5131260 1490892 2016 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Direct and ultrasensitive optofluidic-based immunosensing assay of aflatoxin M1 in dairy products using organic solvent extraction
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Direct and ultrasensitive optofluidic-based immunosensing assay of aflatoxin M1 in dairy products using organic solvent extraction
چکیده انگلیسی


- A simple, low-cost, and reusable optofluidic platform was developed for direct and ultrasensitive immunoassay of AFM1.
- Effect of organic solvents on interaction of antibody-antigen in heterogeneous and homogeneous solutions was evaluated.
- AFM1 can be directly quantified by the proposed platform even if the samples contain a certain organic solvent.
- This method provides the LOD of 5 ng/L for AFM1 in dairy products.
- This method provides a tool for the rapid, accurate, and reliable detection of AFM1 with a simple sample pretreatment.

Aflatoxin M1 (AFM1), a highly toxic secondary metabolite, is present in a wide range of dairy products. In this study, we designed a simple, low-cost, reusable, and easy-to-operate immunosensing method for ultrasensitive detection of AFM1 in dairy products by using a portable evanescent wave-based optofluidic biosensing platform (EOBP). The developed method provides the minimum detection limit of 5 ng/L, which is below the most restrictive standard imposed by the current regulations for AFM1 in dairy products. The effect of several organic solvents, such as methanol, acetone, and acetonitrile, on the binding reaction of antibody-antigen in heterogeneous and homogeneous solutions was evaluated. Although the effect of organic solvents on the homogeneous binding reaction between antibody and antigen is more significant than that of heterogeneous binding reaction between antibody in solution and antigen immobilized onto the sensor surface, the fluorescence signal detected by EOBP is linearly dependent on AFM1 concentration. Therefore, AFM1 can be directly quantified even if the samples contain a certain organic solvent concentration. The robustness and stability of AFM1-ovalbumin conjugate allow the regeneration of modified biosensor surface for more than 200 times, thereby achieving a cost-effective and reliable AFM1 determination. The proposed method provides a rapid, ultrasensitive, and reliable AFM1 determination in dairy products without complicated sample pretreatment process.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 940, 12 October 2016, Pages 120-127
نویسندگان
, , , , , ,