| کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن | 
|---|---|---|---|---|
| 5471195 | 1519388 | 2017 | 35 صفحه PDF | دانلود رایگان | 
عنوان انگلیسی مقاله ISI
												Comparison between exact thermal boundary condition and harmonic mean conductivity condition at the solid-fluid interface for finite thickness shrouded non-isothermal fin array
												
											ترجمه فارسی عنوان
													مقایسه مقادیر مرزی دقیق حرارتی و شرایط هدایت هارمونیک متوسط در رابط مایع جامد برای ضخامت ضخیم آرایه فایبر غیر ایزوترمال پوشیده شده 
													
												دانلود مقاله + سفارش ترجمه
													دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
																																												کلمات کلیدی
												
											موضوعات مرتبط
												
													مهندسی و علوم پایه
													سایر رشته های مهندسی
													مکانیک محاسباتی
												
											چکیده انگلیسی
												A numerical study is made comparing the exact thermal boundary condition and a harmonic mean conductivity condition at the solid-fluid interface for a finite thickness shrouded non-isothermal fin array. Results highlight that there exists a significant deviation of pressure drop across the length of the fin for the exact thermal boundary condition, which is as high as 20% as compared to that obtained using the harmonic mean conductivity condition. The exact thermal boundary condition forecasts relatively more non-isothermal fin as compared to a harmonic mean conductivity condition. The greater the fin spacing the larger the non-isothermal behavior of the fin and it also depends upon Grashof number as well as inlet fluid velocity. The larger the Grashof number the greater is the non-isothermal behavior of fin. The greater the inlet velocity, the larger is the non-isothermal behavior of fin. Bulk fluid temperature is over predicted by as much as 13% by the harmonic mean conductivity condition for larger fin spacing with highest Grashof number coupled with larger velocity. This deviation is only 6% for smaller fin spacing. Overall Nusselt number is over predicted for the harmonic mean conductivity condition as compared to exact thermal boundary condition. This over prediction is limited to about 8%.
											ناشر
												Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Mathematical Modelling - Volume 45, May 2017, Pages 323-335
											Journal: Applied Mathematical Modelling - Volume 45, May 2017, Pages 323-335
نویسندگان
												Kankan Kishore Pathak, Asis Giri, 
											