کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5477549 1521567 2017 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Thoron Mitigation System based on charcoal bed for applications in thorium fuel cycle facilities (part 2): Development, characterization, and performance evaluation
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی هسته ای و مهندسی
پیش نمایش صفحه اول مقاله
Thoron Mitigation System based on charcoal bed for applications in thorium fuel cycle facilities (part 2): Development, characterization, and performance evaluation
چکیده انگلیسی
Exposure due to thoron (220Rn) gas and its decay products in a thorium fuel cycle facility handling thorium or 232U/233U mixture compounds is an important issue of radiological concern requiring control and mitigation. Adsorption in a flow-through charcoal bed offers an excellent method of alleviating the release of 220Rn into occupational and public domain. In this paper, we present the design, development, and characterization of a Thoron Mitigation System (TMS) for industrial application. Systematic experiments were conducted in the TMS for examining the 220Rn mitigation characteristics with respect to a host of parameters such as flow rate, pressure drop, charcoal grain size, charcoal mass and bed depth, water content, and heat of the carrier gas. An analysis of the experimental data shows that 220Rn attenuation in a flow through charcoal bed is not exponential with respect to the residence time, L/Ua (L: bed depth; Ua: superficial velocity), but follows a power law behaviour, which can be attributed to the occurrence of large voids due to wall channeling in a flow through bed. The study demonstrates the regeneration of charcoal adsorption capacity degraded due to moisture adsorption, by hot air blowing technique. It is found that the mitigation factor (MF), which is the ratio of the inlet 220Rn concentration (Cin) to the outlet 220Rn concentration (Cout), of more than 104 for the TMS is easily achievable during continuous operation (>1000 h) at a flow rate of 40 L min−1 with negligible (<1 cm of water column) pressure drop. The Thoron Mitigation System based on adsorption on charcoal bed offers a compact and effective device to remove 220Rn from affluent air streams in a space constrained domain. The prototype system has been installed in a thorium fuel cycle facility where it is being evaluated for its long-term performance and overall effectiveness in mitigating 220Rn levels in the workplace.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Environmental Radioactivity - Volume 172, June 2017, Pages 249-260
نویسندگان
, , , , , ,