کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5485751 1399439 2016 21 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Systematic Performance Evaluation of a Cross-Correlation-Based Ultrasound Strain Imaging Method
ترجمه فارسی عنوان
ارزیابی عملکرد سیستماتیک یک روش تصویربرداری با سونوگرافی مبتنی بر همبستگی
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم آکوستیک و فرا صوت
چکیده انگلیسی
Estimation of tissue motion in the lateral direction remains a major challenge in 2-D ultrasound strain imaging (USI). Although various methodologies have been proposed to improve the accuracy of estimation of in-plane displacements and strains, the fundamental limitations of 2-D USI and how to choose optimal algorithmic parameters in various tissue deformation paradigms to retrieve the full strain tensor of acceptable accuracy are scattered throughout the literature. Thus, this study attempts to provide a systematic investigation of a 2-D cross-correlation-based USI method in a theoretical framework. Our previously developed cross-correlation-based USI method was revisited, and additional estimation strategies were incorporated to improve in-plane displacement and strain estimation. The performance of the presented method using different matching kernel sizes (axial: from 1λ to 14λ, where λ = wavelength; lateral: from 1 to 13 pitches) and two data formats (radiofrequency and envelope) in various kinematic scenarios (normal, shear or hybrid deformation) was investigated using Field II simulations, in which coherent plane wave compounding with 64 steered angles was realized. For radiofrequency-based USI, smaller axial and larger lateral kernel sizes were preferred in scenarios with normal strains, whereas larger kernel sizes along the shearing direction and smaller ones orthogonal to the shearing direction were more suitable in scenarios with shear strains. For envelope-based USI, in contrast, the kernel size requirement was relatively relaxed. A compromise between optimal kernel sizes and estimation accuracy of various strain components was required in complex kinematic scenarios. These practical strategies for accurate motion estimation using 2-D cross-correlation-based USI were further tested in a tissue-mimicking phantom under quasi-static compression and in a preliminary in vivo examination of a normal human median nerve at the wrist during active finger motion.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ultrasound in Medicine & Biology - Volume 42, Issue 10, October 2016, Pages 2436-2456
نویسندگان
, , ,