کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5726321 1609730 2017 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Non-contrast-enhanced magnetic resonance venography using magnetization-prepared rapid gradient-echo (MPRAGE) in the preoperative evaluation of living liver donor candidates: Comparison with conventional computed tomography venography
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی رادیولوژی و تصویربرداری
پیش نمایش صفحه اول مقاله
Non-contrast-enhanced magnetic resonance venography using magnetization-prepared rapid gradient-echo (MPRAGE) in the preoperative evaluation of living liver donor candidates: Comparison with conventional computed tomography venography
چکیده انگلیسی


- MPRAGE-MRV and CTV showed similar performance in evaluation of RL-LDLT without MHV.
- MPRAGE-MRV tended to show more venous tributaries than conventional CTV.
- MPRAGE-MRV could replace CTV for preoperative evaluation of living liver donors.

ObjectiveTo compare the diagnostic performance of non-contrast-enhanced magnetic resonance venography using magnetization-prepared rapid gradient-echo (MPRAGE-MRV) and conventional computed tomography venography (CTV) in preoperative evaluation of venous tributaries for living donor liver transplantation.Materials and methodsInstitutional review board approval and written informed consent were obtained for this prospective study of 73 donor candidates. Of these, 23 underwent right-sided graft hepatectomy without middle hepatic vein. One or more tributaries, other than the right hepatic vein, were reconstructed for 20 of the 23 grafts. For these 20 grafts, the number and location of the tributaries requiring reconstruction were evaluated based on venography, and diagnostic performance was analyzed using surgical records as a reference standard. For each candidate, the number of small tributaries directly joining the inferior vena cava was counted in each venographic image; a paired-sample t-test was used to assess differences. The severity of respiratory artifacts in MPRAGE-MRV was qualitatively evaluated, and compared using Wilcoxon's rank-sum test.ResultsAll reconstructed venous tributaries were prospectively identified using both methods. MPRAGE-MRV tended to provide a greater number of small tributaries than conventional CTV (mean: 2; 95% CI: [1.66, 2.34], and 1.74; [1.44, 2.04], respectively), although the difference was not significant (P = 0.10); MPRAGE-MRV was superior or equal to CTV in 52 subjects (71.2%), and inferior in 21 subjects (28.8%). Respiratory artifacts were significantly less severe in the former subjects (P < 0.0001).ConclusionsMPRAGE-MRV has the potential to replace conventional CTV in the preoperative evaluation of living liver donor candidates.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Radiology - Volume 90, May 2017, Pages 89-96
نویسندگان
, , , , , , ,