کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
5819865 | 1557361 | 2014 | 7 صفحه PDF | دانلود رایگان |
According to the ICH Q8 guideline, analytic technologies (PAT) are important tools for characterization and optimization of pharmaceutical manufacturing processes. Particle size as a critical quality attribute for granules is therefore an important parameter that should be monitored during the fluid bed granulation process. This work focusses on optimizing position and configuration of an SFT-sensor for the in-line measurement of particle size distribution in a Glatt GPCG 3 fluid bed granulator. As model-substances, different grades of microcrystalline cellulose were used. The in-line measured particle size and particle rate in the sensor were evaluated. A sensor position in the deceleration zone of the granulator was found to be promising for in-line particle size measurement. Most reliable data were generated in this position when the probe was placed in a distance of 11Â cm from the chamber wall to avoid bias by the inlet air stream. No major influence of rotation angle of the probe was found in this position. Furthermore, an entire fluid bed granulation process was successfully monitored with the sensor installed in the optimized setting.
230
Journal: International Journal of Pharmaceutics - Volume 466, Issues 1â2, 15 May 2014, Pages 31-37