کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6243089 1609764 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Three-dimensional contrast enhanced ultrasound score and dynamic contrast-enhanced magnetic resonance imaging score in evaluating breast tumor angiogenesis: Correlation with biological factors
ترجمه فارسی عنوان
بررسی کنتراست سه بعدی افزایش نمره سونوگرافی و ترسیم تصویری رزونانس مغناطیسی با کنتراست پویا در ارزیابی آنژیوژنز تومور پستان: همبستگی با عوامل بیولوژیکی
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی رادیولوژی و تصویربرداری
چکیده انگلیسی

ObjectiveTo explore the clinical value of three-dimensional contrast enhanced ultrasound (3D-CEUS) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) score systems in evaluating breast tumor angiogenesis by comparing their diagnostic efficacy and correlation with biological factors.Methods3D-CEUS was performed in 183 patients with breast tumors by Esaote Mylab90 with SonoVue (Bracco, Italy), DCE-MRI was performed on a dedicated breast magnetic resonance imaging (DBMRI) system (Aurora Dedicated Breast MRI Systems, USA) with a dedicated breast coil. 3D-CEUS and DCE-MRI score systems were created based on tumor perfusion and vascular characteristics. Microvessel density (MVD), vascular endothelial growth factor (VEGF) and matrix metalloproteinases (MMP-2, MMP-9) expression were measured by immunohistochemistry.ResultsPathological results showed 35 benign and 148 malignant breast tumors. MVD (P = 0.000, r = 0.76), VEGF (P = 0.000, r = 0.55), MMP-2 (P = 0.000, r = 0.39) and MMP-9 (P = 0.000, r = 0.41) expression were all significantly different between benignity and malignancy. Regarding 3D-CEUS 4 points as cutoff value, the sensitivity, specificity and accuracy were 85.1%, 94.3% and 86.9%, respectively, and correlated well with MVD (P = 0.000, r = 0.50), VEGF (P = 0.000, r = 0.50), MMP-2 (P = 0.000, r = 0.50) and MMP-9 (P = 0.000, r = 0.66). Taking DCE-MRI 5 points as cutoff value, the sensitivity, specificity and accuracy were 86.5%, 94.3% and 88.0%, respectively and also correlated well with MVD (P = 0.000, r = 0.52), VEGF (P = 0.000, r = 0.44), MMP-2 (P = 0.000, r = 0.42) and MMP-9 (P = 0.000, r = 0.35).Conclusions3D-CEUS score system displays inspiring diagnostic performance and good agreement with DCE-MRI scoring. Moreover, both score systems correlate well with MVD, VEGF, MMP-2 and MMP-9 expression, and thus have great potentials in tumor angiogenesis evaluation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Radiology - Volume 83, Issue 7, July 2014, Pages 1098-1105
نویسندگان
, , , , , , ,