کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6391153 | 1628411 | 2015 | 6 صفحه PDF | دانلود رایگان |

- HPLC-fluorescence was used in the determination of melamine in UHT bovine milk.
- Melamine shows an intense natural fluorescence at 250/365Â nm.
- Extracts of milk samples were obtained using an acid precipitation treatment.
- The analytical method showed very good figures of merit.
- The developed method is simple with high throughput regardless the matrix complexity.
A method of high performance liquid chromatography with fluorescence detection (HPLC-Fluo), based on previous studies of the natural fluorescence emission of melamine (250/365 nm), was developed and validated for melamine determination as an adulterant of bovine UHT whole milk. The clean up treatment of milk samples by deproteinization was thoroughly optimized. No matrix effect was observed and a linear range from 0.05 to 10.0 μg mLâ1 was obtained, with a value of R2 equal to 0.9998. The limits of detection and quantification of melamine were 0.0081 and 0.027 μg mLâ1 respectively, or 0.023 and 0.076 μg gâ1 of milk, respectively, considering the sample dilution during extraction. Extracts of milk samples fortified with melamine at three concentration levels, two of which corresponded to the levels established by WHO for melamine in foods, led to an overall mean recovery of 95.4 ± 1.2% (n = 9). This recovery value satisfies the performance criteria established by the Codex Alimentarius for analytical methods suitable for determination of food residues, demonstrating the usefulness and effectiveness of the proposed method.
Journal: Food Control - Volume 51, May 2015, Pages 402-407