Sub cooling of PCM due to various effects during solidification in a vertical concentric tube thermal storage unit
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Sub cooling of PCM due to various effects during solidification in a vertical concentric tube thermal storage unit
چکیده انگلیسی

Phase Change Materials (PCMs), in the solidification/melting temperature range of 19 °C–22 °C, have been considered suitable for the free cooling application of buildings. Further, these phase change materials operate over a narrow range of temperatures, and hence, the sub cooling effect of the PCM plays an important role in the efficient design of heat storage devices. In the present experimental work, the sub cooling effect of PCM-RT 21 was studied in a vertical concentric tube heat storage unit. It was observed that the PCM experienced different cooling rates at different axial heights, with the highest rate near the Heat Transfer Fluid (HTF) entry region. Also, the higher cooling rate increased the sub cooling effect and lowered the solidification temperature of the PCM. The experimentally observed solidification temperatures under different cooling rates correlated well with the values arrived at, using the DSC analysis. The free convection during the liquid sensible cooling commenced the nucleation process at all the radial locations of the PCM at a particular axial height, at the same time, without much difference in the onset of the solidification temperature. The time span of the temperature plateau during the latent heat release increased on increasing the radial location of the PCM from the heat transfer surface, as the heat transport rate decreased. It was further found that when the driving temperature potential between the PCM and the HTF was high, the increase in the inlet velocity of the HTF beyond a certain value had a negligible effect during the liquid sensible cooling and the subsequent solidification process.


► The sub cooling effect of PCM-RT21 was studied in a concentric tube heat storage unit.
► The PCM closer to entry region, experienced higher cooling rate and larger sub cooling.
► At any cooling rate the experiment and DSC analysis showed same freezing temperature.
► The radially farthest located PCM had high temperature plateau with larger time span.
► The velocity of the HTF beyond a certain value had a negligible effect on sub cooling.