کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6477140 1426595 2016 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Sensitive and selective voltammetric determination of anti˗cancer agent shikonin on sepiolite clay/TiO2 nanoparticle/MWCNTs composite carbon paste sensor and investigation of its electro˗oxidation mechanism
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Sensitive and selective voltammetric determination of anti˗cancer agent shikonin on sepiolite clay/TiO2 nanoparticle/MWCNTs composite carbon paste sensor and investigation of its electro˗oxidation mechanism
چکیده انگلیسی


- A new carbon paste electrode modified with Sepiolite clay, TiO2 nanoparticles, and multi˗walled carbon nanotubes was developed.
- A simple and sensitive methodology was developed to determine the SHI by using AdsDPV.
- It was firstly reported on the electrochemical properties of SHI on clay/TiO2/MWCNTs/CPE sensor.

A simple and highly sensitive voltammetric method was developed to determine the Shikonin (SHI) content in synthetic and real samples. The method is based on a carbon pate electrode (CPE) modified by the addition of sepiolite clay, TiO2 nanoparticles and multi-walled carbon nanotubes (MWCNTs). Differential puls adsorptive stripping voltammetry (AdsDPV) technique was employed with the electrode as the anode. Furthermore, electrochemical redox properties of SHI were investigated by using cyclic voltammetry (CV) on the same electrode. The CV studies show that SHI has two quasi-reversible oxidation signals at about − 0.100 V (P1) and + 0.700 V (P2) in acidic media. To the best of our knowledge, the oxidation peak P1 has not been observed in previous voltammetric studies on SHI. We suggest mechanisms that lead to both P1 and P2. The peak P1 was selected for the quantitative analysis of SHI on the electrode concerned, because it is more intense than P2 (higher peak current, higher sensitivity). P1 is also the choice in terms of interference effects of several organic compounds likely to be present in biological samples. The anodic peak current of SHI in AdsDPV varies linearly with the concentration range of 0.44-1000 n mol L− 1. Dedection (LOD) and quantification (LOQ) limits were calculated as 0.13 n mol L− 1 and 0.44 n mol L− 1, respectively. The voltammetric technique was applied to SHI analysis in human urine and serum samples and found to produce expectable quality results.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Electroanalytical Chemistry - Volume 780, 1 November 2016, Pages 38-45
نویسندگان
, , ,