کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
647965 1457190 2011 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Counterflow logarithmic mean temperature difference is actually the upper bound: A demonstration
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Counterflow logarithmic mean temperature difference is actually the upper bound: A demonstration
چکیده انگلیسی

The logarithmic mean temperature difference (ΔTLM or LMTD) is a corner stone concept used in the design and analysis of heat transfer equipment, such as heat exchangers. The LMTD methods are well established in the Chemical Engineering framework and, in general, apply a counterflow LMTD corrected by some factor to assess the “true” mean temperature difference between the fluids exchanging heat. The counterflow LMTD is used because it is undoubtedly believed that its value for two countercurrent streams is higher than when the same streams are arranged in concurrent flow. Although this principle may be supported by direct comparison between the counterflow and parallel flow LMTD’s for any given process conditions, a demonstration of its universal validity is not found in the literature. This article presents a proof founded in mathematical and physical arguments that this belief is indeed a fact.

Research highlights
► The LMDT for counterflow is always greater than the parallel flow value.
► Mathematical demonstration was shown for n”

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 31, Issues 6–7, May 2011, Pages 1172–1175
نویسندگان
, ,