کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6606012 459522 2016 39 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Synthesis of Surface Molecularly Imprinted Poly(methacrylic acid-hemin) on Carbon Nanotubes for the Voltammetric Simultaneous Determination of Antioxidants from Lipid Matrices and Biodiesel
ترجمه فارسی عنوان
سنتز پلی مگنزر سطحی (متاکریلیک اسید-هیمن) بر روی نانولوله های کربنی برای تعیین ولتاژ و اندازه گیری آنتی اکسیدان ها از ماتریس های لیپیدی و بیودیزل
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
چکیده انگلیسی
This paper reports the synthesis of novel nanocomposite based on multi-walled carbon nanotubes (MWCNT) covalently bonded by molecularly imprinted poly(methacrylic acid-hemin) (MIP-MWCNT) using tert-butylhydroquinone (TBHQ) as template molecule and its use in the construction of electrochemical sensor. Chemical, physical and morphological structure of nanocomposite was characterized by FT-IR, TGA, SEM, TEM and textural analysis. The electrochemical sensor highly selective to TBHQ was prepared by drop-casting a suspension of nanocomposite on the surface of a glassy carbon electrode. From cyclic voltammetry, it was observed that the electrochemical sensor modified with MIP-MWCNT exhibited great recognition performance, higher analytical response and catalytic properties towards the TBHQ when compared to NIP-MWCNT (nanocomposite polymerized without adding TBHQ), MIP-MWCNT without hemin and MIP-hemin without MWCNT. Such results demonstrated the synergic effect of imprinting influence, MWCNT and hemin in improving the performance of electrochemical sensor. From chronoamperometric measures, the electrochemical sensor modified with MIP-MWCNT could recognize TBHQ selectively in the presence of electroactives and structurally similar compounds. Under optimized conditions by pulse differential voltammetry (pulse amplitude of 100 mV, pulse time of 25 ms and scan rate of 10 mV s−1) and measures in 0.15 mol L−1 H2SO4, the proposed method successfully enabled the simultaneous determination of TBHQ and butylated hydroxyanisole (BHA), yielding limits of detection of 0.85 and 0.50 μmol L−1, respectively. The feasibility of the method was checked by simultaneous determination of TBHQ and BHA in soybean oil, margarine, mayonnaise and biodiesel, whose results were statistically equal to those achieved by high performance liquid chromatography (HPLC).
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Electrochimica Acta - Volume 212, 10 September 2016, Pages 322-332
نویسندگان
, , , , , , , ,