کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6782136 1432265 2018 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Optimization of switch modes of fully enclosed platform screen doors during emergency platform fires in underground metro station
ترجمه فارسی عنوان
بهینه سازی حالت های سوئیچ در درب های پلت فرم به طور کامل محصور در حین حملات اضطراری در ایستگاه مترو زیرزمینی
کلمات کلیدی
آتش سوزی ایستگاه مترو، حالت سوئیچ، بهینه سازی،
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات مهندسی ژئوتکنیک و زمین شناسی مهندسی
چکیده انگلیسی
Fire is a major hazard in an underground metro station. Faced with challenges from fires in metro stations, platform screen doors (PSDs) are usually installed on the ground, which are critical to passengers' life safety. In case of a platform fire, in order to get optimal control of smoke and provide better environmental conditions for evacuation, the operation of those PSDs needs to be systematically studied. In this work, Fire Dynamics Simulator (FDS) was used to investigate the smoke exhaust effect during fires in underground island-type platform under twenty-four different PSD switch modes. The parameters that influence evacuee life safety, such as temperature and visibility contours at the stair entrance, were computed to compare the performance of different switch modes for the underground metro station with fully enclosed PSDs. The simulation results show that the optimization of the PSD switch modes in the underground metro station depends significantly on the cooperation of the air supply system in the lobby floor, the air exhaust system in the platform floor and the tunnel. Three potential fire sources in the platform floor have been studied. When the fire source is in the center of the subway platform, it is better to open four end doors and 12 PSDs in one side, or open all PSDs in one side during the developing stage of fire. As for its stable stage of fire, it is better to open four end doors or all PSDs in one side. When the fire source is near the ends of the platform, it is better to open all PSDs in one side or open four end doors during the developing stage of fire. As for its stable stage of fire, it is better to open all PSDs in both sides near the fire sources. Those results can provide some guidance to the smoke control design in case of platform fire in the underground metro station.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Tunnelling and Underground Space Technology - Volume 81, November 2018, Pages 277-288
نویسندگان
, , , , ,