کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
683404 888999 2009 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Prediction of membrane fouling in MBR systems using empirically estimated specific cake resistance
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی تکنولوژی و شیمی فرآیندی
پیش نمایش صفحه اول مقاله
Prediction of membrane fouling in MBR systems using empirically estimated specific cake resistance
چکیده انگلیسی

The focus of this study was to empirically estimate the specific cake resistance (SCR) by the variation in shear intensity (G) in four laboratory-scale MBRs. The control reactor (MBR0) was operated with aeration only while other MBRs (MBR150, MBR300 and MBR450) were operated with aeration and mechanical mixing intensities of 150, 300 and 450 rpm, respectively. It was found that the SCR was strongly correlated (R2 = 0.99) with the fouling rates in the MBRs. Moreover, the contribution of cake resistance (Rc) to the total hydraulic resistance (Rt) was predominant compared to the irreversible fouling resistance (Rf). On this basis, the cake filtration model was selected as a predictive tool for membrane fouling. This model was modified by replacing the SCR with its empirical shear intensity relationship. The modified model can predict the fouling rate for a given shear intensity (G) within 80 and 250 s−1 in a MBR system.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Bioresource Technology - Volume 100, Issue 23, December 2009, Pages 6133–6136
نویسندگان
, , ,