کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7608532 1493383 2018 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Urea functionalized surface-bonded sol-gel coating for on-line hyphenation of capillary microextraction with high-performance liquid chromatography
ترجمه فارسی عنوان
پوشش پلی اتیلن سطحی وابسته به ادرار برای برش خط بر روی میکروکاکساسیون مویرگی با کروماتوگرافی مایع با کارایی بالا
کلمات کلیدی
سل ژل، میکرو اکستراسیون مویرگی، میکروکاکساکتیو فاز جامد درون لوله، پوشش کاربردی اوره رطوبت گرادیان، تجزیه و تحلیل کروماتوگرافی مایع مغناطیسی میکرو اکستراسیون آنلاین، تشخیص فوق العاده بنفش
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی
Sol-gel urea functionalized-[bis(hydroxyethyl)amine] terminated polydimethylsiloxane coating was developed for capillary microextraction-high performance liquid chromatographic analysis from aqueous samples. A fused silica capillary is coated from the inside with surface bonded coating material and is created through in-situ sol-gel reaction. The urea-functionalized coating was immobilized to the inner surface of the capillary by the condensation reaction of silanol groups of capillary and sol-solution. The characterization of the coating material was successfully done by using X-ray photoelectron spectroscopy, thermogravimetric analysis, field emission scanning electron microscope, and energy dispersive X-ray spectrometer. To make a setup of online capillary microextraction-high performance liquid chromatography, the urea functionalized capillary was installed in the HPLC manual injection port. The analytes of interest were pre-concentrated in the coated sampling loop, desorbed by the mobile phase, chromatographically separated on C-18 column, and analyzed by UV detector. Sol-gel coated capillaries were used for online extraction and high-performance liquid chromatographic analysis of phenols, ketones, aldehydes, and polyaromatic hydrocarbons. This newly developed coating showed excellent extraction for a variety of analytes ranging from highly polar to non-polar in nature. The analysis using sol-gel coating showed excellent overall sensitivity in terms of lower detection limits (S/N = 3) for the analytes (0.10 ng mL−1-14.29 ng mL−1) with acceptable reproducibility that is less than 12.0%RSD (n = 3). Moreover, the capillary to capillary reproducibility of the analysis was also tested by changing the capillary of the same size. This provided excellent%RSD of less than 10.0% (n = 3).
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1543, 30 March 2018, Pages 14-22
نویسندگان
, ,