کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7626697 1494583 2018 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Wavenumber selection method to determine the concentration of cocaine and adulterants in cocaine samples
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Wavenumber selection method to determine the concentration of cocaine and adulterants in cocaine samples
چکیده انگلیسی
Street cocaine is typically altered with several compounds that increase its harmful health-related side effects, most notably depression, convulsions, and severe damages to the cardiovascular system, lungs, and brain. Thus, determining the concentration of cocaine and adulterants in seized drug samples is important from both health and forensic perspectives. Although FTIR has been widely used to identify the fingerprint and concentration of chemical compounds, spectroscopy datasets are usually comprised of thousands of highly correlated wavenumbers which, when used as predictors in regression models, tend to undermine the predictive performance of multivariate techniques. In this paper, we propose an FTIR wavenumber selection method aimed at identifying FTIR spectra intervals that best predict the concentration of cocaine and adulterants (e.g. caffeine, phenacetin, levamisole, and lidocaine) in cocaine samples. For that matter, the Mutual Information measure is integrated into a Quadratic Programming problem with the objective of minimizing the probability of retaining redundant wavenumbers, while maximizing the relationship between retained wavenumbers and compounds' concentrations. Optimization outputs guide the order of inclusion of wavenumbers in a predictive model, using a forward-based wavenumber selection method. After the inclusion of each wavenumber, parameters of three alternative regression models are estimated, and each model's prediction error is assessed through the Mean Average Error (MAE) measure; the recommended subset of retained wavenumbers is the one that minimizes the prediction error with maximum parsimony. Using our propositions in a dataset of 115 cocaine samples we obtained a best prediction model with average MAE of 0.0502 while retaining only 2.29% of the original wavenumbers, increasing the predictive precision by 0.0359 when compared to a model using the complete set of wavenumbers as predictors.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 152, 15 April 2018, Pages 120-127
نویسندگان
, , , , , , ,