کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
768491 | 1462990 | 2013 | 6 صفحه PDF | دانلود رایگان |

• We study on pipeline corrosion in oil-water mixture medium of oil field.
• The corrosion rate of weight loss of the steel disc is calculated.
• The microstructure of the corrosion products are investigated by EDS and XRD.
• The surface of metal after corrosion is observed by SEM.The reason of corrosion is analyzed.
Corrosion perforation and scaling occur frequently in pipeline of Tuha oil field. After being exposed to crude oil in petroleum transmission pipeline for 120 days, corrosion rate of weight loss of the steel disc was calculated. Scanning Electron Microscope (SEM) was employed to observe the microscopic corrosion morphology of coupon, and the compositions of the oily water mixture and pipes were analyzed. The microstructure of the corrosion products and the reason of corrosion were investigated by Energy Dispersive Spectroscopy (EDS) and X-ray Diffraction (XRD). The result showed that non-uniform corrosion occurred on the surface of coupon, and corrosion rate of weight loss was 0.187 mm/y The corrosion products was mainly ferrous sulfide (FeS) and silicon disulfide (SiS2), and the scaling was mainly calcium carbonate (CaCO3). The corrosion-cell reaction, calcium ion (Ca2+) and bicarbonate ion (HCO3-) in formation water, and sulfuretted hydrogen (H2S) were the major factors which caused pipeline corrosion and scaling. H2S and Ca2+ weakened carbon dioxide (CO2) corrosion of pipeline in oil–water mixture medium.
Journal: Engineering Failure Analysis - Volume 34, December 2013, Pages 35–40