کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
770067 897445 2009 16 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Failure investigation of secondary super-heater tubes in a power boiler
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Failure investigation of secondary super-heater tubes in a power boiler
چکیده انگلیسی

This study investigates a failure case in El-Kureimat thermal power station unit number 2 which experienced secondary super-heater tube failures. The failed tubes were reportedly found to be weeping during an operating pressure hydrostatic test, performed after a repair of another boiler component. The failure analysis indicated that the 304H tube leakage was due to stress corrosion cracking. The cracked tubes were studied and found to have undergone sensitization due to either welding or heat treatment of bent parts. Both service-exposed and laboratory specimens were studied in the current work.The service exposed samples that exhibited cracking were removed from the foresaid boiler. The laboratory specimens were used to verify proposed failure sequence and to evaluate the susceptibility of this alloy to sensitization. A correlation was made between artificially sensitized samples and stress corrosion cracking mechanism.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Engineering Failure Analysis - Volume 16, Issue 1, January 2009, Pages 433–448
نویسندگان
, , , ,