کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7915800 1511025 2017 23 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Process configuration of Liquid-nitrogen Energy Storage System (LESS) for maximum turnaround efficiency
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد مواد الکترونیکی، نوری و مغناطیسی
پیش نمایش صفحه اول مقاله
Process configuration of Liquid-nitrogen Energy Storage System (LESS) for maximum turnaround efficiency
چکیده انگلیسی
Diverse power generation sector requires energy storage due to penetration of variable renewable energy sources and use of CO2 capture plants with fossil fuel based power plants. Cryogenic energy storage being large-scale, decoupled system with capability of producing large power in the range of MWs is one of the options. The drawback of these systems is low turnaround efficiencies due to liquefaction processes being highly energy intensive. In this paper, the scopes of improving the turnaround efficiency of such a plant based on liquid Nitrogen were identified and some of them were addressed. A method using multiple stages of reheat and expansion was proposed for improved turnaround efficiency from 22% to 47% using four such stages in the cycle. The novelty here is the application of reheating in a cryogenic system and utilization of waste heat for that purpose. Based on the study, process conditions for a laboratory-scale setup were determined and presented here.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Cryogenics - Volume 88, December 2017, Pages 132-142
نویسندگان
, , ,