کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7916069 1511052 2014 24 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Emissivity of silver and stainless steel from 80 K to 300 K: Application to ITER thermal shields
موضوعات مرتبط
مهندسی و علوم پایه مهندسی مواد مواد الکترونیکی، نوری و مغناطیسی
پیش نمایش صفحه اول مقاله
Emissivity of silver and stainless steel from 80 K to 300 K: Application to ITER thermal shields
چکیده انگلیسی
The emissivities of thermal shield mock-up samples for ITER have been measured at sample temperatures between 80 K and 300 K using an optical method employing a primary standard broadband detector. These thermal shields, made from SS304L stainless steel coated with silver, are designed to operate at 80 K, protecting the superconducting magnet system of the ITER reactor from higher temperature regions. Our results show that the silver coating of the thermal shields can have an emissivity as low as 0.0035 at 80 K, approximately ten times lower than the emissivity of the bare polished stainless steel plate. We demonstrate that the emissivity of different regions of a thermal shield assembly can be determined in a single measurement cycle, providing further emissivity data on the insulating spacer used to separate shield plates as well as emissivity data on a silver coating repair method. The temperature dependence of the emissivity for the silver coating agrees well with a theoretical estimate based on the Drude model including phonon and surface-assisted scattering.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Cryogenics - Volume 60, March–April 2014, Pages 44-48
نویسندگان
, , , ,