Calculation of Coincidence Summing Correction Factors for an HPGe detector using GEANT4
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی هسته ای و مهندسی
پیش نمایش صفحه اول مقاله
Calculation of Coincidence Summing Correction Factors for an HPGe detector using GEANT4
چکیده انگلیسی
The aim of this paper was to calculate the True Coincidence Summing Correction Factors (TSCFs) for an HPGe coaxial detector in order to correct the summing effect as a result of the presence of 88Y and 60Co in a multigamma source used to obtain a calibration efficiency curve. Results were obtained for three volumetric sources using the Monte Carlo toolkit, GEANT4. The first part of this paper deals with modeling the detector in order to obtain a simulated full energy peak efficiency curve. A quantitative comparison between the measured and simulated values was made across the entire energy range under study. The True Summing Correction Factors were calculated for 88Y and 60Co using the full peak efficiencies obtained with GEANT4. This methodology was subsequently applied to 134Cs, and presented a complex decay scheme.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Environmental Radioactivity - Volumes 158–159, July 2016, Pages 114-118