کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8895298 | 1629899 | 2017 | 11 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
An improved thermo-time domain reflectometry method for determination of ice contents in partially frozen soils
ترجمه فارسی عنوان
یک روش بازتابی اندازه گیری دمای زمانی برای تعیین محتویات یخ در خاک های منجمد شده است
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
علوم زمین و سیارات
فرآیندهای سطح زمین
چکیده انگلیسی
Measuring ice contents (θi) in partially frozen soils is important for both engineering and environmental applications. Thermo-time domain reflectometry (thermo-TDR) probes can be used to determine θi based on the relationship between θi and soil heat capacity (C). This approach, however, is accurate in partially frozen soils only at temperatures below â5â¯Â°C, and it performs poorly on clayey soils. In this study, we present and evaluate a soil thermal conductivity (λ)-based approach to determine θi with thermo-TDR probes. Bulk soil λ is described with a simplified de Vries model that relates λ to θi. From this model, θi is estimated using inverse modeling of thermo-TDR measured λ. Soil bulk density (Ïb) and thermo-TDR measured liquid water content (θl) are also needed for both C-based and λ-based approaches. A theoretical analysis is performed to quantify the sensitivity of C-based and λ-based θi estimates to errors in these input parameters. The analysis indicates that the λ-based approach is less sensitive to errors in the inputs (C, λ, θl, and Ïb) than is the C-based approach when the same or the same percentage errors occur. Further evaluations of the C-based and λ-based approaches are made using experimentally determined θi at different temperatures on eight soils with various textures, total water contents, and Ïb. The results show that the λ-based thermo-TDR approach significantly improves the accuracy of θi measurements at temperatures â¤â5â¯Â°C. The root mean square errors of λ-based θi estimates are only half those of C-based θi. At temperatures of â1 and â2â¯Â°C, the λ-based thermo-TDR approach also provides reasonable θi, while the C-based approach fails. We conclude that the λ-based thermo-TDR method can reliably determine θi even at temperatures near the freezing point of water (0â¯Â°C).
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Hydrology - Volume 555, December 2017, Pages 786-796
Journal: Journal of Hydrology - Volume 555, December 2017, Pages 786-796
نویسندگان
Zhengchao Tian, Tusheng Ren, Yuki Kojima, Yili Lu, Robert Horton, Joshua L. Heitman,