کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8948181 | 1645649 | 2018 | 21 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay for simultaneous quantifications of CZ48, lactone-stabilized camptothecin, and camptothecin and their pharmacokinetic and biliary evaluations in rats
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
![عکس صفحه اول مقاله: Ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay for simultaneous quantifications of CZ48, lactone-stabilized camptothecin, and camptothecin and their pharmacokinetic and biliary evaluations in rats Ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay for simultaneous quantifications of CZ48, lactone-stabilized camptothecin, and camptothecin and their pharmacokinetic and biliary evaluations in rats](/preview/png/8948181.png)
چکیده انگلیسی
CZ48, a prodrug of camptothecin (CPT), has a broad spectrum of antitumor activity against various types of human tumors without severe toxicity in preclinical human tumor-xenografted mouse models, which facilitates further preclinical and clinical pharmacokinetic (PK) evaluations of CZ48. In this study, a UHPLC-MS/MS method was developed and validated to simultaneously quantify CZ48 and CPT in rat plasma and bile. Detection was performed using the API 3200 Q Trap triple quadrupole mass spectrometer in a positive ion mode. Chromatographic separation was achieved on Waters ACQUITY UPLC BEH Shield RP18 column with a gradient elution at a flow rate of 0.45âml/min, using mobile phases of 0.1% acetic acid in water (A) and 0.1% acetic acid in acetonitrile (B). The method was linear at the concentration ranges of 0.98 (LLOQ) â1000âng/ml of CZ48 and CPT in rat plasma and 3.9 (LLOQ) â1000âng/ml in bile. Intra- and inter-day accuracy and precision values did not deviate by more than 6.57% and 10.15% for CZ48 and CPT, respectively, in plasma, and 12.09% and 13.48% in bile. Extraction recoveries of CZ48 were 90.18-95.42% from plasma and 86.51 â91.66% from bile. The recoveries of CPT were 91.56-97.06% from plasma and 84.89-89.15% from bile. No significant matrix effects were observed in plasma and bile within 14.00% and 16.19%, respectively. CZ48 and CPT in plasma were stable after extraction process and different storage conditions, including bench-top, processed sample in autosampler, three cycles of freeze and thaw, and long-term (3 month) stability at â80â°C. The application of the validated method was demonstrated by a PK study after an intravenous dose of CZ48 in rats.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 161, 30 November 2018, Pages 122-128
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 161, 30 November 2018, Pages 122-128
نویسندگان
Yu Jin Kim, Yifan Tu, Diana S.-L. Chow,