کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
9632557 462121 2005 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Monitoring of an industrial liquid-liquid extraction system with kernel-based methods
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Monitoring of an industrial liquid-liquid extraction system with kernel-based methods
چکیده انگلیسی
The behaviour of liquid-liquid extraction systems can be complex and as a result linear methods of process condition monitoring such as principal component analysis or partial least squares may not be able to detect and identify process faults when they occur. In contrast, kernel-based methods represent a general framework that can be used where linear methods do not perform satisfactorily. This is demonstrated in a case study on an industrial liquid-liquid extraction system, where a linear discriminant analysis problem is recast as a support vector machine learning problem. The support vector machine is subsequently used to extract features from the plant data that can be used for considerably more accurate fault detection than is possible with its linear equivalent or with other nonlinear methods. Fault identification can be accomplished from an analysis of the residuals of models using the features to reconstruct the original plant data.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Hydrometallurgy - Volume 78, Issues 1–2, July 2005, Pages 41-51
نویسندگان
, ,