کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
10552217 | 967192 | 2005 | 13 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Characterization and quantification of Bcl-2 antisense G3139 and metabolites in plasma and urine by ion-pair reversed phase HPLC coupled with electrospray ion-trap mass spectrometry
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
TEAAOligodeoxynucleotidesPhosphorothioate oligonucleotideCoefficients of variationsSOSHFIPMRMmRNACVSIP-RP-HPLCLOQCIDESI1,1,1,3,3,3-hexafluoro-2-propanol - 1،1،1،3،3،3-هگزافلوئورو 2-پروپانولODNs - ODN هاmessenger RNA - RNA messengerTriethylammonium acetate - استات TriethylammoniumTEAB - بدانیدtriethylammonium bicarbonate - بی کربنات تری اتیل آمونیومtriethylamine - تری اتیلامینContinuous intravenous infusion - تزریق داخل وریدی مداومEnzyme-linked immunosorbent assay - تست الیزاELISA - تست الیزاcollision induced dissociation - تقارن ناشی از برخوردTandem mass spectrometry - طیف سنجی جرمی پشت سر هم یا متوالیPharmacokinetics - فارماکوکینتیکLod - لودMetabolism - متابولیسم limit of quantification - محدودیت اندازه گیریlimit of detection - محدودیت تشخیصmultiple reaction monitoring - نظارت چندگانه چندگانهTEA - چایelectrospray ionisation - یونیزاسیون الکترو اسپری
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
چکیده انگلیسی
A novel ion-pair reversed phase electrospray ionization (IP-RP-ESI) liquid chromatography-mass spectrometry (LC-MS) method has been developed for identification and quantification of Bcl-2 antisense phosphorothioate oligonucleotides G3139 and metabolites in plasma. This method utilized solid phase extraction for desalting and matrix removal and detection by an ion trap mass spectrometer. Resolution was accomplished on a micro C18 column eluted with a mobile phase consisting of hexafluoro-2-propanol and triethylamine in methanol at 50 °C. Five G3139 metabolites were identified in plasma and urine from treated patients and rats. A cassette HPLC-MS/MS quantification method for G3139 and three metabolites was developed and validated with a limit of quantification (LOQ) of 17.6 nM in human and rat plasma with acceptable precision and accuracy. Plasma pharmacokinetics of G3139 and metabolites in these species were described.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 825, Issue 2, 25 October 2005, Pages 201-213
Journal: Journal of Chromatography B - Volume 825, Issue 2, 25 October 2005, Pages 201-213
نویسندگان
Guowei Dai, Xiaohui Wei, Zhongfa Liu, Shujun Liu, Guido Marcucci, Kenneth K. Chan,