کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
11000147 | 1422141 | 2018 | 24 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
DNA mixtures interpretation - A proof-of-concept multi-software comparison highlighting different probabilistic methods' performances on challenging samples
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
علوم زیستی و بیوفناوری
بیوشیمی، ژنتیک و زیست شناسی مولکولی
ژنتیک
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
The present study investigated the capabilities and performances of semi-continuous and fully-continuous probabilistic approaches to DNA mixtures interpretation, particularly when dealing with Low-Template DNA mixtures. Five statistical interpretation software, such as Lab Retriever and LRmix Studio - involving semi-continuous algorithms - and DNA
- VIEW®, EuroForMix and STRmixTM- employing fully-continuous formulae - were employed to calculate likelihood ratio, comparing the prosecution and the defense hypotheses relative to a series of on-purpose prepared DNA mixtures that respectively contained 2 and 3 known contributors. National Institute of Standards and Technologies (NIST) certified templates were used for samples set up, which contained different DNA amounts for each contributor. 2-person mixtures have been prepared with proportions equal to 1:1, 19:1 and 1:19 in terms of DNA concentration. Conversely, three person mixtures were constituted by proportions equal to 20:9:1, 8:1:1, 6:3:1 and 1:1:1 in terms of DNA concentration. Furthermore, 8 equally-proportioned 3-person mixtures were prepared by means of scalar dilutions starting from an overall amount of 0.500âng, then ranging up to DNA samples with concentrations equal to 0.004âng (i.e. Low-Template DNA). DNA mixtures were set up in triplicate and amplified with 7 DNA amplification kits (i.e. GlobalFiler PCR Amplification Kit, NGM SElect PCR Amplification Kit, MiniFiler PCR Amplification Kit, Power Plex Fusion, PowerPlex 6C Matrix System, Power Plex ESI 17 Fast and Power Plex ESX 17 Fast) in order to evaluate whether the selection of a certain kit might represent a bias factor, capable of altering the whole interpretation process. A multi-software approach helped us to highlight any trend in the likelihood ratio results provided by semi- and fully-continuous software. As a matter of fact, fully-continuous computations provided different (higher) results in terms of degrees of magnitude of the likelihood ratio values with respect to those from the semi-continuous approach, regardless of the amplification kit that was utilized.
- VIEW®, EuroForMix and STRmixTM- employing fully-continuous formulae - were employed to calculate likelihood ratio, comparing the prosecution and the defense hypotheses relative to a series of on-purpose prepared DNA mixtures that respectively contained 2 and 3 known contributors. National Institute of Standards and Technologies (NIST) certified templates were used for samples set up, which contained different DNA amounts for each contributor. 2-person mixtures have been prepared with proportions equal to 1:1, 19:1 and 1:19 in terms of DNA concentration. Conversely, three person mixtures were constituted by proportions equal to 20:9:1, 8:1:1, 6:3:1 and 1:1:1 in terms of DNA concentration. Furthermore, 8 equally-proportioned 3-person mixtures were prepared by means of scalar dilutions starting from an overall amount of 0.500âng, then ranging up to DNA samples with concentrations equal to 0.004âng (i.e. Low-Template DNA). DNA mixtures were set up in triplicate and amplified with 7 DNA amplification kits (i.e. GlobalFiler PCR Amplification Kit, NGM SElect PCR Amplification Kit, MiniFiler PCR Amplification Kit, Power Plex Fusion, PowerPlex 6C Matrix System, Power Plex ESI 17 Fast and Power Plex ESX 17 Fast) in order to evaluate whether the selection of a certain kit might represent a bias factor, capable of altering the whole interpretation process. A multi-software approach helped us to highlight any trend in the likelihood ratio results provided by semi- and fully-continuous software. As a matter of fact, fully-continuous computations provided different (higher) results in terms of degrees of magnitude of the likelihood ratio values with respect to those from the semi-continuous approach, regardless of the amplification kit that was utilized.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Forensic Science International: Genetics - Volume 37, November 2018, Pages 143-150
Journal: Forensic Science International: Genetics - Volume 37, November 2018, Pages 143-150
نویسندگان
E. Alladio, M. Omedei, S. Cisana, G. D'Amico, D. Caneparo, M. Vincenti, P. Garofano,