کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1163567 1490945 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Direct infusion electrospray ionization–ion mobility–mass spectrometry for comparative profiling of fatty acids based on stable isotope labeling
ترجمه فارسی عنوان
اسپکترومتری جابجایی یونیزاسیون مستقیم الکترو اسپری مستقیم برای مقایسه اسیدهای چرب با استفاده از برچسب ایزوتوپ پایدار
کلمات کلیدی
برچسب زدن ایزوتوپ پایدار، اسیدهای چرب، یونیزاسیون الکترو اسپری، طیف سنجی جرمی یون
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• A novel method based on IM–MS and SIL was developed for FAs comparative profiling.
• Without LC separation, the method allowed direct infusion profiling of FAs in complex samples.
• Both of the efficiency and accuracy for FAs analyses were favorably enhanced by IM–MS and SIL.
• A significant increased content level of FFAs was confirmed in thyroid cancerous tissues.

A rapid method for fatty acids (FAs) comparative profiling based on carboxyl-specific stable isotope labeling (SIL) and direct infusion electrospray ionization–ion mobility–mass spectrometry (ESI–IM–MS) is established. The design of the method takes advantage of the three-dimensional characteristics of IM–MS including drift time, m/z and ion intensity, for comparison of d0-/d6-2,4-dimethoxy-6-piperazin-1-yl pyrimidine (DMPP)-labeled FAs. In particular, without chromatographic separation, the method allowed direct FAs profiling in complex samples due to the advantageous priority of DMPP in signal enhancement as well as the extra resolution that IM–MS offered. Additionally, the d0-/d6-DMPP-labeled FAs showed expected features, including very similar drift times, 6 Da mass deviations, specific reporter ions, similar MS responses, and adherence to the drift time rule regarding the influence of carbon chain length and unsaturation on relative drift times. Therefore, the introduction of isotope analogs minimized the matrix effect and variations in quantification and ensured accurate identification of non-targeted FAs by those typical features. Peak intensity ratios between d0-/d6-DMPP-labeled ions were subsequently used in relative quantification for the detected FAs. The established strategy has been applied successfully in the rapid profiling of trace free FAs between normal and cancerous human thyroid tissues. Sixteen free FAs were found with the increased level with a statistically significant difference (p < 0.05) compared to the normal tissue samples. The integrated SIL technique and ESI–IM–MS are expected to serve as an alternative tool for high-throughput analysis of FAs in complex samples.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 887, 5 August 2015, Pages 148–154
نویسندگان
, , , , , , , , ,