کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1163610 1490944 2015 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Fast determination of hydroxylated polychlorinated biphenyls in human plasma by online solid phase extraction coupled to liquid chromatography-tandem mass spectrometry
ترجمه فارسی عنوان
تعیین سریع بفنیل های پلی کربنات هیدروکسیل شده در پلاسمای انسان از طریق استخراج فاز جامد آنلاین به وسیله اسپکترومتر جرمی کروماتوگرافی مایع
کلمات کلیدی
طیف سنجی جرمی کروماتوگرافی مایع دو طرفه، پلاسمای انسانی، قرار گرفتن در معرض شغلی، متابولیسم فنیل کلراید بفنیل، دیفنیل های پلی کربنات هیدرولیکی شده، اختلال غدد درون ریز
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• We developed an online SPE-LC-MS/MS method for OH-PCB determination in human plasma.
• The method required only 100 μL of plasma and minimal sample preparation steps.
• 3OH-PCB 28 has been synthesized and identified for the first time in plasma.
• Penta-through hepta-chlorinated OH-PCBs were the predominant congeners.
• Notable presence of unknown OH-PCB congeners in several plasma samples.

Hydroxylated polychlorinated biphenyls (OH-PCBs) have been shown to be strongly retained in human blood causing endocrine-related toxicity, particularly on the thyroid system. Traditionally, analytical methods for the determination of OH-PCBs require labor-intensive and long-time consuming sample preparation with several extraction, evaporation and cleanup procedures steps and, in some cases, derivatization prior to the analysis by gas or liquid chromatography-mass spectrometry (GC–MS or LC-MS). The present study developed and validated a novel, sensitive and high throughput online solid phase extraction (SPE) method coupled to LC-tandem mass spectrometry (MS/MS) for the separation and quantitation of relevant congeners of OH-PCBs in human plasma. The developed method presented limits of quantification (LOQ) ranging from 0.02 to 0.5 ng mL−1 and extraction recoveries from 71 to 134% for all congeners, requiring small amount of sample (only 100 μL) and minimal sample preparation. In order to evaluate the applicability of the method, preliminary tests (N = 93) were conducted in plasma from individuals occupationally exposed to very high levels of PCBs in a German cohort. Penta-through hepta-chlorinated OH-PCBs were the predominant congeners in human plasma with concentrations up to 44.5 ng mL−1, while lower chlorinated OH-PCBs were occasionally detected. In addition, a new PCB 28 metabolite has been synthesized and identified for the first time in human plasma and associations between OH-PCBs and their parent compounds in the studied cohort were also assessed.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 888, 12 August 2015, Pages 94–102
نویسندگان
, , , , , ,