Gold nanoparticle–antibody conjugates for specific extraction and subsequent analysis by liquid chromatography–tandem mass spectrometry of malondialdehyde-modified low density lipoprotein as biomarker for cardiovascular risk
ترجمه فارسی عنوان
اسپکترومتری دو طرفه از لیپوپروتئین کم چگالی اصلاح شده مالون دی آلدئید به عنوان بیومارکر برای خطر قلبی عروقی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Generic platform for nanoimmunoaffinity extraction of biomarkers developed.
• Application to extract malondialdehyde-modified low-density lipoprotein.
• After extraction (oxidized) (phospho) lipids are analyzed by LC–MS/MS.
• Comparison of random and oriented immobilization of antibodies on gold nanoparticle.
• Optimized binding properties for oriented immobilization via Cys-modified protein A.

Oxidized low-density lipoproteins (OxLDLs) like malondialdehyde-modified low-density lipoprotein (MDA-LDL) play a major role in atherosclerosis and have been proposed as useful biomarkers for oxidative stress. In this study, gold-nanoparticles (GNPs) were functionalized via distinct chemistries with anti-MDA-LDL antibodies (Abs) for selective recognition and capture of MDA-LDL from biological matrices. The study focused on optimization of binding affinities and saturation capacities of the antiMDA-LDL-Ab-GNP bioconjugate by exploring distinct random and oriented immobilization approaches, such as (i) direct adsorptive attachment of Abs on the GNP surface, (ii) covalent bonding by amide coupling of Abs to carboxy-terminated-pegylated GNPs, (iii) oriented immobilization via oxidized carbohydrate moiety of the Ab on hydrazide-derivatized GNPs and (iv) cysteine-tagged protein A (cProtA)-bonded GNPs. Depending on immobilization chemistry, up to 3 antibodies per GNP could be immobilized as determined by ELISA. The highest binding capacity was achieved with the GNP-cProtA-Ab bioconjugate which yielded a saturation capacity of 2.24 ± 0.04 μg mL−1 GNP suspension for MDA-LDL with an affinity Kd of 5.25 ± 0.11 × 10−10 M. The GNP-cProtA-antiMDA-LDL bioconjugate revealed high specificity for MDA-LDL over copper(II)-oxidized LDL as well as native human LDL. This clearly demonstrates the usefulness of the new GNP-Ab bioconjugates for specific extraction of MDA-LDL from plasma samples as biomarkers of oxidative stress. Their combination as specific immunoextraction nanomaterials with analysis by LC–MS/MS allows sensitive and selective detection of MDA-LDL in complex samples.