کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1165028 1491058 2013 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Distribution of pesticides in n-hexane/water and n-hexane/acetonitrile systems and estimation of possibilities of their extraction isolation and preconcentration from various matrices
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Distribution of pesticides in n-hexane/water and n-hexane/acetonitrile systems and estimation of possibilities of their extraction isolation and preconcentration from various matrices
چکیده انگلیسی


• The extraction of 150 pesticides in different systems has been investigated.
• The highest and most scattered values of Lg P are observed in hexane/water system.
• The minimal and leveled values of Lg P are observed in hexane/acetonitrile system.
• Conditions of pesticides separation and recovery are estimated on the basis of Lg P.

Distribution of 150 most widely used pesticides of different chemical classes (amides, anilinopirimidines, aromatics, benzenesulfonates, carbamates, dicarboximides, organophosphorus compounds, phenyl esters, phenylureas, pyrazoles, pyrethroids, pyrimidines, strobilurins, sulfamides, triazines, triazoles, etc.) in n-hexane/water and n-hexane/acetonitrile systems was investigated at 25 °C. Distribution constants of pesticides (P) have been calculated as ratio of pesticide concentration in n-hexane to its concentration in water or acetonitrile phase. HPLC and GC methods were used for pesticides determination in phases. It was found that the overwhelming majority of pesticides are hydrophobic, i.e. in n-hexane/water system Lg P ≫ 0, and the difference in Lg P values can reach 9.1 units. Replacement of water for acetonitrile leads to dramatic fall of Lg P values reaching 9.5 units. The majority of Lg P values in this case are negative and their differences is strongly leveled in comparison with a hexane/water system. Thus, maximal difference in pesticides Lg P values for n-hexane/acetonitrile system is 3.2 units. It is shown that n-hexane can be used for selective and efficient extraction and preconcentration of pesticides from water matrices. On the other hand, acetonitrile is effective for the isolation and preconcentration of pesticides from hydrocarbon and vegetable oil matrices. The distribution constants described in the paper may be effectively used for the estimation of possibilities of extraction isolation, preconcentration and separation of pesticides.