کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1165472 | 1491100 | 2012 | 6 صفحه PDF | دانلود رایگان |

This paper reports on the development of an optimized method for the simultaneous analysis of eight biogenic amines (histamine, methylamine, ethylamine, tyramine, putrescine, cadaverine, phenethylamine, and isoamylamine). The analytical method thus proposed has the following advantages: the easy derivatization of wine, the quantification of biogenic amines and a complete degradation of excess derivatization reagent during sample preparation in order to preserve the column. It consists in reversed phase separation by HPLC and UV–vis detection of the aminoenones formed by the reaction of amino compounds with the derivatization reagent diethyl ethoxymethylenemalonate (DEEMM). The usefulness of this technique was confirmed by an alternative oenological analytical method for the validation, quality control and uncertainty assessment (OIV Oeno 10/2005). The method was validated and proposed as a reference method to the International Organization of Vine and Wine (OIV). As a specific application of the proposed method, the biogenic amine content of Rhône valley wines was investigated.
Figure optionsDownload as PowerPoint slideHighlights
► This paper reports on the validation of an optimized method for the biogenic amines analysis.
► During validation, instability of histamine over time was observed.
► As an application, the biogenic amines content in Rhône valley wines was studied.
► This method was proposed to the OIV to become a reference method.
Journal: Analytica Chimica Acta - Volume 732, 30 June 2012, Pages 114–119