کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1166201 1491090 2012 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simultaneous determination of ultraviolet filters in aqueous samples by plunger-in-needle solid-phase microextraction with graphene-based sol–gel coating as sorbent coupled with gas chromatography–mass spectrometry
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Simultaneous determination of ultraviolet filters in aqueous samples by plunger-in-needle solid-phase microextraction with graphene-based sol–gel coating as sorbent coupled with gas chromatography–mass spectrometry
چکیده انگلیسی

A simple, sensitive and selective method for the simultaneous determination of five ultraviolet (UV) filters: benzophenone, octyl salicylate, homosalate, 3-(4-methylbenzylidene) camphor, 2-hydroxy-4-methoxybenzophenone in aqueous samples was developed. The analytes were extracted by plunger-in-needle solid-phase microextraction with graphene as sorbent, then silylated on-fiber with N-methyl-N-(trimethylsilyl)trifluoroacetamide, and analyzed by gas chromatography–mass spectrometry. Factors affecting the performance of extraction and derivatization steps were thoroughly evaluated. For the optimization of extraction conditions, six relevant factors (parameters) were investigated, including sample pH, salt concentration, extraction time, extraction temperature, stirring speed and sampling mode. In the first stage, a two-level orthogonal array design OA8 (27) matrix was employed to study the effect of six factors. Based on the results of the first stage, three factors were selected for further optimization with a univariant approach during the second stage. Under the final optimized conditions, the method limits of detection for the five UV filters were determined to be in the range of 0.5 and 6.8 ng L−1 (at a signal/noise ratio of 3) and the precision (% relative standard deviation, n = 5) was 0.8–5.6% at a concentration level of 1 μg L−1. The linearities for different analytes were 10–10,000 or 1–5000 ng L−1. The coefficients of determination for the calibration curves were all greater than 0.994. Finally, the proposed method was successfully applied to the extraction and determination of the UV filters in river water samples.

Compared with commercial SPME fibers, the sol–gel graphene coating exhibited different selectivity for five UV filters with the log P values in the range of 3.18 and 5.95. Extraction conditions: each UV filter at 10 μg L−1 concentration in aqueous sample, pH = 5, 40-min extraction time, room temperature, direct sampling 0% NaCI, 1000 rpm, n = 3.Figure optionsDownload as PowerPoint slideHighlights
► Five UV filters are simultaneously determined by plunger-in-needle SPME-GC–MS.
► Novel sol–gel graphene is used as sorbent.
► OAD is employed to optimize extraction parameters.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 742, 12 September 2012, Pages 67–73
نویسندگان
, ,