کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1198637 1493476 2016 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Influence of the drying step within disk-based solid-phase extraction both on the recovery and the limit of quantification of organochlorine pesticides in surface waters including suspended particulate matter
ترجمه فارسی عنوان
تأثیر مرحله خشک شدن در استخراج جامد فاز روی دیسک هر دو بر روی بهبود و محدودیت اندازه گیری آفت کش های آلی کلر در آب های سطحی از جمله ذرات معلق
کلمات کلیدی
دیسک استخراج فاز جامد، ماده خاصی معلق است، طیف سنجی جرم کروماتوگرافی گاز، دستورالعمل چارچوب آب، آب سطحی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Method optimisation for analysis of 21 OCPs of the WFD.
• Major focus: drying step to get a residual water content in the SPE disk under 0.01 g.
• Detection limits were in the low ng/L range fulfilling the requirements of the WFD.
• Water samples with SPM up to 500 mg/L were analysed in one step.

In this study, 21 organochlorine pesticides (OCPs) were determined based on sample preparation using solid-phase extraction disks (SPE disks) coupled with programmable temperature vaporizer (PTV)—large-volume injection gas–chromatography mass spectrometry (LVI-GC–MS). The work includes a comprehensive testing scheme on the suitability of the method for routine analysis of surface and drinking water including suspended particulate matter (SPM) with regard to requirements derived from the European Water Framework Directive (WFD, Directive 2000/60/EC). SPM is an important reservoir for OCPs, which contributes to the transport of these compounds in the aquatic environment. To achieve the detection limits required by the WFD, a high pre-concentration factor during sample preparation is necessary, which was achieved by disk SPE in this study. The performance of disk SPE is strongly influenced by the drying step, which could be significantly improved by effective elimination of the residual water by combination of a high vacuum pump and a low humidity atmosphere. Detection limits of the WFD in the ng/L range were achieved by large volume injection of 100 μL sample extract. The recoveries ranged from 82% to 117% with an RSD smaller than 13%. The applicability of this method to natural samples was tested for instrumental qualification and system suitability evaluation. Successful participation in an interlaboratory comparison proved the suitability of the method for routine analysis.